๐Ÿ”งddiyFamily Car Docs
โ† 2019 HYUNDAI ELANTRA

Seat Fan

Open PDF โ†—

- Removal

[Ventilation Blower]

  1. Disconnect the negative (-) battery terminal.
  1. Remove the front seat.
  1. Remove the blower duct.

    image

  1. Remove the blower FAN (A) after removing the screws.

    image

[Ventilation Seat Unit]

  1. Disconnect the negative (-) battery terminal.
  1. Remove the front seat.
  1. Loosening the screws from the ventilation seat unit.

    image

  1. Remove the ventilation seat unit (A) after disconnect the connectors (B).

    image

- Installation

[Ventilation Blower]

  1. Install the blower fan.
  1. Install the duct.
  1. Install the front seat assembly.
  1. Connect the negative (-) battery terminal.

[Ventilation Seat Unit]

  1. Install the ventilation seat unit.
  1. Install the front seat assembly.
  1. Connect the negative (-) battery terminal.

- Inspection

Ventilating seat consists of three units : the ventilating seat unit for control, switch for input and and blower for output.

Diagnosis mode

  1. You can enter the diagnosis mode by turning the heater seat button on.
  1. You can enter the diagnosis mode by referring to following description.
  1. Press the heating wire switch as shown below.
    1. Press and hold the heating wire switch for 3 seconds or more.
    1. Release the switch for 3 seconds or less and press and hold it again for 1.5 - 3 seconds.
    1. Release the switch for 3 seconds or less and press and hold it again for 3 seconds or more.

    image

  1. When the vehicle enters the diagnostic mode, the three LEDs (Low, Mid, High) in the heating wire section blinks once for 0.5 seconds.
    1. When the vehicle enters the self-diagnostic mode, LEDs only work as those for heating wire seat switches.
    1. When two or more errors are detected, the LEDs sequentially blink at a 2-second interval for each error code.

    image

  1. After entering the diagnostic mode, check the LED status to identify the error.

    image

    Failure Indicator
    LED (Flashing)
    Inspection Items
    Detailed Inspections

    image



    image

    Low voltage detection

    Low voltage that deviates from the operating voltage range was supplied.

    Over voltage detection

    Overvoltage that deviates from the operating voltage range was supplied.

    image

    image

    Fuse (Short)


    B+ fuse disconnection




    IGN2 fuse disconnection


    image

    image

    NTC/HEATER MAT
    (Short)
    1. NTC element failure
    1. Heater mat disconnection
    1. Heater+ wiring disconnection
    1. Heater system NTC disconnection (4.9 V or higher)

    image

    image

    NTC/HEATER MAT
    (Disconnector)
    1. Short-circuit between the controller connector terminal and NTC
    1. Short-circuit between the controller connector terminal and heater
    1. Short-circuit in the heater system NTC wiring
    1. Short-circuit in the heater system heater+ wiring

    image

    image

    Target temperature not reached
    Target temperature not reached within 40 minutes

    image

    image

    Short circuit of Ventilation blower power line
    Short circuit of ventilation blower power line (short)

    image

    image

    Power disconnection of ventilation blower
    Disconnection or missing connector of ventilation power line

    image

    image

    Short circuit of ventilation blower speed signal
    Short circuit of ventilation blower speed signal (short)

    image

    image

    Disconnection or missing connector of ventilation blower speed signal
    Disconnection or missing connector of ventilation blower speed signal (VCC)

    image

    image

    Disconnection or missing connector of ventilation blower speed signal
    Disconnection or missing connector of ventilation blower speed signal (GND)

    image

    image

    Short circuit of ventilation blower RPM signal (short)
    Short circuit of ventilation blower RPM signal (short)

    image

    image

    Disconnection or missing connector of ventilation blower RPM signal
    Disconnection or missing connector of ventilation blower RPM signal (GND)

    image

    image

    Disconnection or missing connector of ventilation blower RPM signal
    Disconnection or missing connector of ventilation blower RPM signal (GND)

  1. You can check the malfunctioning by checking the blinking LED.
  1. The failure data is recorded to the memory by the ventilation seat unit.
  1. Press the heating wire seat switch on the passenger side for 5 seconds or more to make the LED blink four times and delete the failure data in the memory.
  1. Pressing the IGN OFF button will end the diagnosis mode for the heater seat.
  1. You can check whether the heating seat system works properly after turning the IGN ON. If you want to check the error code, you can refer to the procedure of 2 above.