- Removal
-
Disconnect the battery negative (-) cable.
-
Disconnect the battery sensor connector (A).
-
Remove the battery negative (-) cable after removing the bolts (B).
- Installation
-
Install in the reverse order of removal.
Battery sensor cable installation bolt :10.8 - 13.7 N.m (1.1 - 1.4 kgf.m, 8.0 -10.1 lb-ft)Battery (-) terminal tightening nut :3.9 - 5.9 N.m (0.4 - 0.6 kgf.m, 2.9 - 4.3 lb-ft)