VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION[LF, L3]

 1. Remove the air hose.
 2. Disconnect the vacuum hose from the variable tumble shutter valve actuator.


image
Click for full-size image
LF


image
Click for full-size image
L3

 3. Connect a vacuum pump to the variable tumble shutter valve actuator.


image
Click for full-size image
 4. Apply vacuum and verify that the rod moves.
    -  If the rod does not move, replace the intake manifold.
VARIABLE INTAKE AIR SHUTTER VALVE ACTUATOR INSPECTION[LF. L3]

 1. Remove the air hose.
 2. Disconnect the vacuum hose from the variable intake air shutter valve actuator.


image
Click for full-size image
LF


image
Click for full-size image
L3

 3. Connect a vacuum pump to the variable intake air shutter valve actuator.


image
Click for full-size image
 4. Apply vacuum and verify that the rod moves.
    -  If the rod does not move, replace the intake manifold.